- HOME >
- Application System >
- Laser Processing >
- Power Supply for Peltier
This is the power supply (supporting CW and pulse) for driving the laser diode (LD). The power supply for
driving a Peltier element and cooling unit all-in-one type required for driving LD is also part of our lineup.
LD Terminal Short Function
Function to short between anode and cathode of LD when power is switched OFF is equipped. By doing it,LD can be protected from static electricity, etc.
Goggle compatible white display
Letters can be displayed in white. Superior in legibility even when using laser-protect goggle.
Instantaneous power failure detection
LD can be safely protected by shutdown operation after instantaneous power failure detection, while there is electric current running after power has been cut off.
Various Alarm Functions
Alarm with screen display equipped enables prompt identification of cause and repair.
LD operation intergrator
LD operation intergrator function equipped, which is essential for LD lifecycle management.Zero reset available for LD replacement.
Full Interface
Interface equipped for setting in a system. Freely externally operable.
Simple Operation
Electric current limit setting and integrated time check can be done from a handle.
Electric current limit settings
Maximum electric current can be set in parameter. It prevents LD damage deriving from malfunction.
Precise digital control, highly efficiency power supply for peltier cooler.
Part Number | JP Yen | Max. output voltage [V] |
Max. output current [A] |
Input voltage [AC V] |
Apparent power [VA] |
Add to Cart |
STDS* | 198,000 | 4 | 1.6 | 85 - 264 | 100 | |
STD3609 | 365,000 | 36 | 9 | 85 - 264 | 600 | |
STD4813 | 376,000 | 48 | 13 | 85 - 264 | 1000 |
* STDS: Maximum output is 3W. Temperature sensor is by thermistor only.
Measurement part | Applicable sensor |
Thermistor or Pt100 (3-wire system) (STDS power supply is for thermister only.) |
Temperature setting accuracy | 0.01℃ | |
AD Converter | 24bit | |
Control part | Control method | Digital PID method |
Control range | -50℃ − 150℃ (according to sensor) | |
Operation ambient temperature | 0℃ - 40℃ | |
Storage ambient temperature | -20℃ - 60℃ | |
Ambient humidity | 20 - 90%RH (No condensation) | |
External dimensions | STD power supply |
(W)200× (H)125× (D)420mm (Excluding projections) |
STDS power supply |
(W)200× (H)65× (D)205mm (Excluding projections) |
|
Interface | RS232C READY contact output |
Measures temperatures with a thermistor or platinum resistance temperature detector, and drives the Peltier device so that the measured temperature becomes the set value.
Equipped with various alarm detection systems and auto tuning function.
Temperature measurement accuracy is 0.01°C. (24bit A/D converter)
For the STD type, both a Pt100 and thermistor can be selected using the parameters.
We do handle orders for manufacturing products with special specifications,
which are not shown in the catalog.
Please contact our sales department.
Part Number | JP Yen | Product Name | Add to Cart |
TMS-1 | 9,000 | Thermistor | |
CHU-1 | 170,000 | Cooling unit |