This is the power supply (supporting CW and pulse) for driving the laser diode (LD). The power supply for
driving a Peltier element and cooling unit all-in-one type required for driving LD is also part of our lineup.
LD Terminal Short Function
Function to short between anode and cathode of LD when power is switched OFF is equipped. By doing it,LD can be protected from static electricity, etc.
Goggle compatible white display
Letters can be displayed in white. Superior in legibility even when using laser-protect goggle.
Instantaneous power failure detection
LD can be safely protected by shutdown operation after instantaneous power failure detection, while there is electric current running after power has been cut off.
Various Alarm Functions
Alarm with screen display equipped enables prompt identification of cause and repair.
LD operation intergrator
LD operation intergrator function equipped, which is essential for LD lifecycle management.Zero reset available for LD replacement.
Full Interface
Interface equipped for setting in a system. Freely externally operable.
Simple Operation
Electric current limit setting and integrated time check can be done from a handle.
Electric current limit settings
Maximum electric current can be set in parameter. It prevents LD damage deriving from malfunction.
Precise digital control environmently friendly, highly efficiency Laser Diode power supply
Developed specifically to drive LD driving.
Includes various functions to protect LD.
Includes various alarms such as instantaneous power failure.
Can be controlled using the front panel and by commands from a PC connected via RS232C.
Includes I/O (Input-Output) for interfacing to external devices and for emergency stop.
Automatic Current Control for stable operation.
Part Number | S$ | Max. output voltage [V] |
Max. output current* [A] |
Input voltage [AC V] |
Apparent power [VA] |
Add to Cart |
SLD0350 | 4,350 | 3 | 50 | 85-264 | 500 | |
SLD0450 | 4,475 | 4 | 50 | 85-264 | 600 | |
SLD0635 | 4,475 | 6.5 | 35 | 85-264 | 600 | |
SLD03A0 | 4,975 | 3 | 100 | 85-264 | 800 | |
SLD04A0 | 4,975 | 4 | 100 | 85-264 | 1000 | |
SLD0670 | 4,975 | 6.5 | 70 | 85-264 | 1000 | |
SLD1045 | 4,975 | 10 | 45 | 85-264 | 1000 | |
SLD1338 | 4,975 | 13 | 38 | 85-264 | 1000 | |
SLD06A0 | 6,225 | 6.5 | 100 | 170-264 | 1800 | |
SLD1078 | 6,225 | 10 | 78 | 170-264 | 1800 | |
SLD1365 | 6,225 | 13 | 65 | 170-264 | 1800 | |
SLD2240 | 6,225 | 22 | 40 | 170-264 | 1800 |
※Minimum current value is approximately 5% of maximum output current.
Control method | High-frequency switching method for CW only |
Output terminal block | M6 |
Current ripple | <0.1%RMS (for maximum output current) (Within the range of maximum output current x 10% or over) |
Current setting accuracy | 0.1A |
Output current error | <1% (for maximum output current) |
Linearity error | <1% (for maximum output current) |
Output current temperature character | <0.03%/℃ (for maximum output current) |
Rise time* | 1sec- |
Fall time* | 1sec- |
Operation ambient temperature | 0℃ - 40℃ |
Storage ambient temperature | -20℃ - 60℃ |
Ambient humidity | 20-90%RH (No condensation) |
External dimensions | (W)200× (H)125× (D)420mm (Excluding projections) |
Interface | RS232C, emergency stop interlock, emission interlock, emission etc. |
Accessory | Jumper connector AC100V cable (For apparent power 1000VA or less only) |
* Please contact our International Sales Division to cut the Rise/Fall time.
We do handle orders for manufacturing products with special
specifications, which are not shown in the catalog.
Please contact our sales department.
Part Number | S$ | Cable Length [m] |
Applicable Model | Add to Cart |
LD50-CA-05 | 75 | 0.5 | SLD0350,SLD0450, SLD0635,SLD1045, SLD1338,SLD2240 |
|
LD50-CA-10 | 100 | 1.0 | ||
LD50-CA-20 | 125 | 2.0 |
Part Number | S$ | Cable Length [m] |
Applicable Model | Add to Cart |
LD100-CA-05 | 88 | 0.5 | SLD03A0,SLD04A0, SLD0670,SLD06A0, SLD1078,SLD1365 |
|
LD100-CA-10 | 113 | 1.0 | ||
LD100-CA-20 | 175 | 2.0 |